CBMSF - PRIME N SEAL, 2603S
- MSDS: CBMSF
- Manufacturer: E I DUPONT DE NEMOURS AND CO
- Product Name: PRIME N SEAL, 2603S
- National Stock Number: 8010-00N070851
Product Identification
Product ID:PRIME N SEAL, 2603S
MSDS Date:10/01/1991
FSC:8010
NIIN:00N070851
MSDS Number: CBMSF
Responsible Party
WILMINGTON, DE 19898
US
Emergency Phone: 800-441-3637;800-424-9300(CHEMTREC)
Info Phone: 800-441-7515
Cage: 0ERJ7
Contractor
Telephone: 800-441-7515;800-441-9442
Cage: 18873
Ingredients
12.5 @ 20C
CAS: 67-63-0
RTECS: NT8050000
OSHA PEL 400 PPM
ACGIH TLV: 400 PPM; 500 STEL
2-BUTANONE; (METHYL ETHYL KETONE) (SARA 313) (CERCLA) VP
CAS: 78-93-3
RTECS: EL6475000
Fraction By Weight: 25%
OSHA PEL 200 PPM
ACGIH TLV: 200 PPM; 300 STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
NONE
OSHA PEL N/K
ACGIH TLV: N/K
2-PROPANOL, 1-METHOXY-; ((PROPYLENE GLYCOL METHYL ETHER)
CAS: 107-98-2
RTECS: UB7700000
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM; 150 STEL
36.7 @ 20C
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 24%
OSHA PEL 200 PPM
ACGIH TLV: 50 PPM, S
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
25 @ 20C
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: 1.5%
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM; 150 STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
5.9 LBS/GAL
RTECS: 9999999VO
OSHA PEL N/K
ACGIH TLV: N/K
NOT BEEN SHOWN TO CAUSE PERIPHERAL NEUROPATHY. LIQ
RTECS: 9999999ZZ
OVEREXP MAY LEAD TO KIDNEY,
RTECS: 9999999ZZ
MAY HAVE INCRD SUSCEPTIBILITY TO TOX OF EXCESS
RTECS: 9999999ZZ
RECURRENT OVEREXP MAY RSLT IN LIVER & KIDNEY INJURY.
RTECS: 9999999ZZ
BEATS IN ANIMALS & OCCAS PALPITATIONS IN HUMANS.
RTECS: 9999999ZZ
HIGH FREQUENCY HEARING DEFICITS; SIGNIFICANCE TO
RTECS: 9999999ZZ
EFTS IN LAB ANIMALS. RECURRENT OVEREXP MAY RSLT IN
RTECS: 9999999ZZ
HARMFUL AMOUNTS.
RTECS: 9999999ZZ
CONTINUOUS SPRAY OPERATIONS ARE TYPICAL OR
RTECS: 9999999ZZ
PRESS, SUPPLIED-AIR RESP (TC-19C). IN ALL CASES,
RTECS: 9999999ZZ
PERMIT ANYONE WITHOUT PROTECTION IN THE PAINTING
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGEST: GI DISTRESS. INHAL: MAY CAUSE
NOSE & THROAT IRRIT. EYE WATERING, HDCHS, NAUS, DIZZ & LOSS OF
COORDINATION ARE SIGNS THAT SOLV LEVELS ARE TOO HIGH. EYES:MAY
CAUSE IRRIT/BURNING. SKIN:RPTD/PRLNG D LIQ CNTCT MAY CAUSE IRRIT
W/DISCOMFORT & DERM. CHRONIC: TOLUENE APPEARS ON THE NAVY LIST OF
OCCUP (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: CHEM REPRO HAZS. SEEK CONSULTATION
FROM APPROP HLTH PROFESSIONALS CONCERNING LATEST HAZ LIST INFO &
SAFE HNDLG & EXPOS INFO . RPTD & PRLNGD OVEREXP TO SOLVS MAY LEAD
TO PERM BRAIN & NE RVOUS SYS DMG. SPECIFIC EFTS:
ISOPROPYLALCOHOL:INGEST STUDIES ON LAB ANIMALS SHOWED VERY HIGH
ORAL DOSES CAUSED(SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INGEST: IN THE UNLIKELY EVENT OF INGESTION, CALL MD
IMMEDIATELY AND HAVE NAMES OF INGREDIENTS AVAILABLE. INHAL: IF
AFFECTED BY INHALATION OF VAPOR OR SPRAY MIST, REMOVE TO FRESH AIR.
IF BREATHING DIFF ICULTY PERSISTS OR OCCURS LATER, CONSULT MD.
EYES: IMMEDIATELY FLUSH WITH PLENTY OF WATER FOR AT LEAST 15
MINUTES, CALL MD. SKIN: WASH WITH SOAP AND WATER. IF IRRITATION
OCCURS, CONTACT MD.
Fire Fighting
Flash Point Method:CC
Flash Point:73.0F,22.8C
Lower Limits:1.0%
Upper Limits:36.7%
Extinguishing Media:WATER SPRAY, FOAM, CARBON DIOXIDE, DRY CHEMICALS.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . WATER FROM FOG NOZZLES MAY BE USED TO COOL
CLOSED CONTAINERS TO PREVENT PRESSURE BUILD UP.
Unusual Fire/Explosion Hazard:WHEN HEATED ABOVE THE FLASH POINT, EMITS
FLAMM VAPS WHICH, WHEN MIXED W/AIR, CAN BURN OR BE EXPLO. FINE
MISTS/SPRAYS MAY BE FLAMM AT TEMPS BELOW FLASH POINT.
Accidental Release
Spill Release Procedures:VENTILATE AREA. REMOVE SOURCES OF IGNITION.
PREVENT SKIN CONTACT AND BREATHING OF VAPOR. WEAR PROPERLY FITTED
NIOSH/MSHA APPROVED VAPOR/PARTICULATE RESPIRATOR (TC-23C). CONFINE
AND REMOVE WITH INERT A BSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:OBSERVE LABEL PRECAUTIONS. KEEP AWAY
FROM HEAT, SPARKS & FLAME. CLOSE CNTNR AFTER EACH USE. GROUND
CNTNRS WHEN POURING. DO NOT STORE ABOVE 120F.
Other Precautions:DO NOT SAND, FLAME CUT, BRAZE OR WELD DRY COATING
WITHOUT A NIOSH/MSHA APPROVED RESPIRATOR OR APPROPRIATE
VENTILATION.
Exposure Controls
Respiratory Protection:DO NOT BREATHE VAPS/MISTS. WEAR NIOSH/MSHA
APPRVD, PROPERLY FITTED VAPOR/PARTICULATE RESP (TC-23C) FOR USE
W/PAINTS DURING APPLICATION & UNTIL ALL VAPS & SPRAY MISTS ARE
EXHAUSTED. IN CONFINED SPACES OR IN SITUATIONS WHERE (ING 16)
Ventilation:PROVIDE SUFFICIENT VENTILATION IN VOLUME & PATTERN TO KEEP
CONTAMINANTS BELOW APPLICABLE OSHA REQUIREMENTS.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
COVERALLS ARE RECOMMENDED.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
EATING OR SMOKING.
Supplemental Safety and Health
% VOLAT: 64.30-87.20. EFTS OF OVEREXP:INCRD LIVER & KIDNEY WTS. METHYL
ETHYL KETONE:HIGH CONCS HAVE CAUSED EMBRYOTOX EFTS IN LAB ANIMALS.
METHYL ETHYL KETONE HAS BEEN SHOWN TO POTENTIATE (IE SHORTEN T IME
OF ONSET) THE PERIPHERAL NEUROPATHYCAUSED BY EITHER N-HEXANE OR
METHYL N-BUTYL KETONE. MEK BY ITSELF HAS (ING 8)
Chemical Properties
Boiling Pt:B.P. Text:>172F,>78C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:0.85-1.23
Evaporation Rate & Reference:LESS THAN ETHER
Solubility in Water:MISCIBLE
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:SUPDAT
Stability
Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORESEEABLE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
SMOKE.
Disposal
Waste Disposal Methods:DO NOT ALLOW MATERIAL TO CONTAMINATE GROUND
WATER SYSTEMS. INCINERATE ABSORBED MATERIAL IN ACCORDANCE WITH
FEDERAL, STATE AND LOCAL REQUIREMENTS. DO NOT INCINERATE IN CLOSED
CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.